`ice_interfaces` compared the operator's entry against ifaddr's
`adapter.name` only -- the kernel name on Linux (`wlp3s0f0`), but the adapter
GUID on Windows (`{846EE342-...}`). A setting written on Linux, or copied
into a Windows node's node.toml, matched no adapter at all.
The failure was silent and total rather than partial: aioice binds one socket
per host address, so an empty list means no sockets, no host candidates, and
an SDP offering only a reflexive address. The settings field is free text
with no picker, and on Windows the operator sees neither the GUID nor the
description -- `ipconfig` shows the connection name -- so an entry now
matches the adapter name, the device description, or one of the adapter's own
IPv4 addresses, case-insensitively. An address is the one identifier visible
on every platform.
A filter that matches nothing now falls back to the unfiltered list with a
warning. Losing the 5 s timeout saving is a regression; being silently
unconnectable is a defect.
Also fixes IPv4/IPv6 discrimination in the same loop: the two were told apart
by falling through to an `elif` that index-probed `ip.ip[0]` and `ip.ip[2]`,
which on an IPv4 str yields characters that compared unequal by luck rather
than by design. Now discriminated by isinstance.
WINDOWS-PORT.md claimed Transport had "no platform dependency"; it does.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01DtfG7z6wHWj8RKHCvxQtY1
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
`npm run dist:win` produces MeshBay-Setup-<version>.exe: the Electron client
and, beside it under resources/node-runtime/, the frozen meshbay-node daemon
(meshbay-common inside it). No hub. Per-user, no elevation — matches the W3
constraint that a logon-triggered scheduled task needs admin.
electron-builder / package.json
build.win nsis, build/icon.ico, extraResources -> node-runtime/
build.nsis oneClick:false perMachine:false allowElevation:false
allowToChangeInstallationDirectory:true
dist:win -> packaging/win/build-win.ps1 (mirrors dist -> build-client.sh)
packaging/win/
meshbay-node.spec + node-entry.py PyInstaller freeze of
meshbay_node.daemon:main. The awkward deps (aiortc, av, aioquic,
pydantic_core, uvicorn, watchdog, guessit, blake3, tzdata) are pulled
in whole with collect_all — that list is expected to grow when a frozen
run raises ModuleNotFoundError.
build-node-runtime.ps1 throwaway venv -> pip install -> PyInstaller ->
packages/meshbay-client/node-runtime/ (gitignored)
build-win.ps1 Node>=22 check, npm ci, Electron bump, sync-ui,
node runtime, electron-builder --win nsis
bump-electron.mjs the Chromium-CVE "build against latest Electron"
policy, out of the PS script (5.1 here-string terminator rules)
README.md
PyInstaller, not the python-embed zip: the frozen meshbay-node.exe is a
genuine relocatable single binary, which is what src/main.js:findNodeBinary
spawns (process.resourcesPath/node-runtime/meshbay-node.exe when packaged) and
what the W3 autostart launcher points at. The embeddable zip needs pip to make
that wrapper and the wrapper bakes in an absolute interpreter path.
build/installer.nsh: on uninstall, taskkill meshbay-node.exe and delete the W3
Startup .vbs (it would point wscript at a deleted binary every sign-in).
%LOCALAPPDATA%\meshbay\ — node.toml, keystore.enc — is never touched.
ffmpeg is not bundled by default (node finds it on PATH); build-win.ps1
-FfmpegDir copies ffmpeg.exe/ffprobe.exe in for a self-contained installer.
Verified on the Windows guest: PyInstaller freeze builds first try
(node-runtime 147 MB), frozen `meshbay-node status` talks to the live daemon's
loopback API; electron-builder --win nsis produces MeshBay-Setup-0.1.0.exe
(155 MB), oneClick/perMachine flags applied, node-runtime bundled at the path
findNodeBinary expects. test_packaging_win.py (14) pins the config invariants
and the NSIS <-> platform.py autostart seam. Node suite 798 pass / 34 skip.
Open: Authenticode signing (13.9 — unsigned => SmartScreen), Windows CI
(18.3), electron-updater. First clean-machine install + DPAPI + autostart
round-trip is a manual check.