| Commit message (Collapse) | Author | Age | Files | Lines |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Most of these failed on Windows for reasons that had nothing to do with the
code under test, which is how real Windows defects hid among them:
- Read and write files as UTF-8, and talk to Node in UTF-8. read_text(),
write_text() and subprocess text=True use the locale codepage, cp1252 on
Windows: "é", "—" and "→" arrived as "?" or crashed, some sixty tests.
Calls to PowerShell and schtasks are left alone -- they answer in the
console codepage.
- Import ESM harness modules by file URL (as_uri): a raw "C:\..." path is not
a module specifier.
- test_cli_golden: mask the tmp path in its JSON-escaped form, spell it the
POSIX way, record on Linux, mask the protocol version (the recording had
failed everywhere since the MNP 4.0 bump) and argparse's version-dependent
quoting; point USERPROFILE at the tmp home, or `member invite` and
`operator pair` wrote their codes into the developer's profile.
- test_disk_io_off_loop: expect what a free loop can reach on the platform's
timer, 15.6 ms on Windows, not an assumed 5 ms.
- test_root_paths_are_operator_only: expect the OS's spelling of the path.
- test_audio_meta_cache: find ffprobe with shutil.which.
Node suite on Windows: 1489 passed, none failed. Hub suite: 3 failures left,
all older than this change (two SQLite concurrency tests, one transfer resume).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Most of what the relay says repeats without bound — a line every fiftieth
fragment for the length of a film, one per dropped fragment whenever a client
falls behind — and it lands in the terminal the app was started from. Those go
through `debuglog` now, restored with:
NODE_DEBUG=cast-relay npm start
The loss of fMP4 framing stays on console.warn. It recovers by rescanning, so
nothing throws and no other part of the system hears about it; that line is the
only trace that the picture on the television is missing a piece. Every other
failure here throws, and the renderer already reports the rejection.
The logging guard now covers both cast modules, each with the one line it is
meant to keep audible.
Also corrects the header comment, which still claimed CORS was granted on the
subtitle path only. It has been on both since the stream needed it too.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01UGY17EPph5LsLzePPXhUVc
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
The receiver reports its state on a timer, so `player status: PLAYING` repeats
for as long as a film runs and buries everything else in the terminal the app
was started from. The progress lines now go through Node's own `debuglog`,
which costs nothing when disabled — the message is never formatted — and is
restored with:
NODE_DEBUG=cast-chromecast npm start
The socket error stays on console.error. It fires when the connection to the
receiver dies and is the only trace of why a cast stopped; routing it through
the same switch would make the one failure worth seeing the one that
disappears.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01UGY17EPph5LsLzePPXhUVc
|
|
|
The relay forwards the node's fragments untouched, and those begin at zero
at the seek point. The player never notices because its SourceBuffer is given
`timestampOffset = start`; a receiver has no equivalent, so the cues are
shifted by `-start` before they leave, recomputed at every restart of the
relay. Sent as they are, a subtitle would be out by the whole seek.
The document is served from the relay's own port at /subs.vtt, behind the same
token as the stream and with CORS: a receiver fetches a side-loaded track with
XHR from its own origin, and without the headers it fails as a network error
with nothing on screen to say so. The URL carries a version because a track is
cached by address — changing the cues behind a fixed URL leaves the previous
language showing.
Cues that end before the stream begins are dropped rather than clamped, so a
line from before the seek cannot appear over the first frames after it.
The relay is plain Node, so the tests start it and fetch from it rather than
reading its source.
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01UGY17EPph5LsLzePPXhUVc
|